English | 简体中文
B2B Global Marketing
  
   
 
公告新訊息
張貼採購公告
張貼銷售公告
依日期列表
買物者商機
賣物者公告
依分類列表
買物者分類
賣物者分類



內容


Enlarge

[CN] LDC-X200 Laser Diameter Measuring System Jun 7, 2024

LDC-X200 Laser Diameter Measurement System



Overview

The non-contact diameter measuring system, is mainly used in the measurement of the outer diameter of various wire rods, bars, wires and pipes. The system can detect the change of the diameter (outer diameter) of the measured object in real time under the high temperature state.



The working principle

The diameter measuring system takes the laser scanning method as an example. It adopts the probe imported from Japan, which can achieve an accuracy of plus or minus 2 microns in the range of 0.3 to 30 mm. The acquisition frequency reaches 2000 times/second. The probe uses a self-excited infrared light source, which overcomes the measurement problem in dim environments.

It adopts the measurement method of pulse parallel light scanning, and has a strong ability to resist the jitter of the measured object. (As shown in Figure 1) Since the shaking frequency of the measured object is much smaller than the scanning frequency, when the measured object A moves in the shakeable area, the measurement result will be able to ensure its accuracy because the time it blocks the beam does not change.



Figure 1: Probe Scanning Radiation Area



The detection principle is as follows



Figure 2: Working Principle



First, the crystal oscillator generates self-excited high-frequency pulses, which are sent to the comparator and the stepping servo motor respectively. The stepping servo motor drives the octahedral prism to rotate at a high speed, and reflects the infrared laser emitted by the laser generator to the convex lens A. It becomes parallel light, and then collects on the photosensitive element C through the convex lens B in the infrared receiving probe. The photosensitive element C converts this signal into a corresponding electrical signal and sends it to the other end of the comparator to compare with the original signal.

When there is no object to be measured in the measuring probe, the pulse signal at both ends of the comparator will be the same. Therefore, there is no difference output: when there is an object to be measured in the measuring probe, the photosensitive element C will output no pulse signal during the period of scanning through the object to be measured. Therefore, there will be a difference input for a period of time at both ends of the comparator, which corresponds to the diameter of the measured object. By calculating the oscillation period of the pulse and the length of the time slice without pulse, the diameter of the measured object can be known.





The composition and functions of the system

The system consists of the following main parts (as shown in Figure 1)



1. A measurement frame with four pairs of high-frequency laser scanning probes and non-contact infrared thermometers is installed

2. Four intelligent signal processors connected with four pairs of high frequency laser scanning probes

3. Cold air blowing system for cooling and cleaning the measuring frame

4. High-performance intelligent controller responsible for front-end data signal processing and network communication

5. Data processing and analysis system installed with industrial grade PC, monitor and printer
公司資訊
公司名稱: 
Wuhan CenterRise M&C Engineering CO., Ltd. (點擊查看公司資訊)
連絡人:  Floria Liang
網址:  *******************
Email:  聯絡我們
電話:  ***************
傳真:  *******
國家:  [CN]
住址:  Building 4, Hengxin Industrial Park, No. 8 Xinhua Avenue, Huangpi District, Wuhan, Hubei Province, China 432200



Commerce 會員:
請登入您的帳號與密碼
 
帳號
密碼 :
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主題
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他,請詳細說明:
*安全密碼
請輸入所顯示的安全密碼



. .   網站導覽  l  隱私權政策  l  服務團隊  l  合作提案  l  聯絡我們  l  幫幫我  l  廣告刊登  l  B2B商業夥伴   . .
Copyright©2024, G.T. Internet Information Co., Ltd. All Rights Reserved.