登入 加入會員 求助
 
Zhejiang Ailipu Technology Co., LTD.
 
 
Recommended Results 
 
Phosphate Injection Diaphragm Dosing Pump 

  產品分類 : 機械與設備->整廠設備輸出->大底整廠設備及規劃

     
Phosphate Injection Diaphragm Dosing Pump
       

  產品規格
 
Model No:    JXM-A-22/1.2
  Country  CN
  Brand  AILIPU
  Packing  Strong carton suitable for international transportationG.W.:20KG/Set
  Minimum Order  5
  Payment Term  L/C,T/T

 

  產品描述
   
  <div>
</div>
<div>
<div style="vertical-align:top;">
<div id="d3fjl" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-5wi47" style="padding:8px 0 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Product Description
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="o4x3c">
<p>
&nbsp;After finishing the above mentioned checks, users can start the metering pump and also should observe&nbsp;and listen attentively to the pump.
</p>
<p class="MsoNormal">
Users can loosen the stroke set screw on the adjusting carrier so as to control the flow rate by adjusting the 0.001mm interval scale. As for the JXM-A type pumps, to true&nbsp;clockwise is to increase the flow rate, while for the JZM-A type pumps, to turn clockwise is to decrease the flow rate. All the stroke adjusting scopes are marked in percentage and the minimum interval on the handle is 1%. For adjusting the handle to reach a suitable flow rate, users should tighten up the set screw so as to maintain the flow rate.
</p>
<p>
<br />
</p>
</div>
</div>
<div>
<div id="f50k8">
<div style="font-family:&quot;vertical-align:top;margin-left:-4px;">
<div id="rdai1">
<div>
<div id="rdai1">
<table class="MsoNormalTable" style="font-family:&quot;width:538pt;">
<tbody>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
<br />
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
l/h
</p>
</td>
<td width="103" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
&nbsp;&nbsp;(Mpa)
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
&nbsp;
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
(mm)
</p>
</td>
<td width="99" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
(mm)
</p>
</td>
<td width="88" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
(KW)
</p>
</td>
<td width="67" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
(KG)
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 2.25/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
2.25
</p>
</td>
<td width="103" valign="center" rowspan="5" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
1.2
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
36
</p>
</td>
<td width="79" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
1.2
</p>
</td>
<td width="99" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
DN8
</p>
</td>
<td width="88" valign="center" rowspan="9" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
0.37KW
</p>
</td>
<td width="67" valign="center" rowspan="12" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
18
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 4.5/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
4.5
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
&nbsp;
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 9/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
9
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 22/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
22
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
72
</p>
</td>
<td width="79" valign="center" rowspan="2" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
4
</p>
</td>
<td width="99" valign="center" rowspan="5" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
DN15
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 44/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
44
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 85/1.0
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
85
</p>
</td>
<td width="103" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
1
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
72
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
6
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 120/0.7
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
120
</p>
</td>
<td width="103" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
0.7
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
72
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
8
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 170/0.7
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
170
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
6
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 240/0.7
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
240
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
8
</p>
</td>
<td width="99" valign="center" rowspan="4" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
DN25
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 315/0.5
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
315
</p>
</td>
<td width="103" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
0.5
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
8
</p>
</td>
<td width="88" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
0.55KW
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 400/0.5
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
400
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" rowspan="2" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
10
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 500/0.5
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
500
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
180
</p>
</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<div>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/05/01/d4/5fcc0b285939b426aeba8e51a1.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=25&p=9&t=80&text=emphaWxpcHUuYm9zc2dvby5jb20%3D" width="750" height="416" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</p>
<p>
<br />
</p>
<div id="f5fer" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-0mb6c" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Products Show
</div>
</div>
<p>
<br />
</p>
<p>
<br />
</p>
</div>
</div>
<div>
<div id="eo1lz">
<div id="ali-anchor-AliMaya-comt4">
</div>
</div>
<div>
<div id="91l29">
<div>
<img src="http://i.bosscdn.com/uploads/ed/e9/b9/ab46793ce69e8a25d25ffccaf3.jpg" width="750" height="444" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
<div>
<div id="jhnu2">
<img src="http://i.bosscdn.com/product/68/57/47/3704401139a0aa0c8b8af88350.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=25&p=9&t=80&text=emphaWxpcHUuYm9zc2dvby5jb20%3D" width="750" height="500" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" /><br />
</div>
</div>
<div>
<div>
<div id="hepim">
<h3>
Technical Specifications
</h3>
</div>
<div id="ukd6q">
<p>
* Flow rates up to 500L/H, pressure up to 12Bar<br />
* Adjustment of flowrate from 0% - 100% while running or stopped<br />
* Accuracy +/- 2% of 100% rated flow<br />
* Mechanically actuated PTFE diaphragm<br />
* Maximum temperature of pumped fluid: +10℃ - 40℃<br />
* Maximum suction up to 2M
</p>
</div>
</div>
</div>
<div>
<div>
<div id="esde4">
<h3>
Features &amp; Benefits
</h3>
</div>
<div id="cslyb">
<p>
* Mechanical actuated diagragm design, easy operation and with the convenience maintanence<br />
* Changeable eccentric drive, no leakage with security delivery<br />
* Rugged construction designed to withstand tough environments<br />
* Oil bath lubrication for all of drive components<br />
* Various pump head material (PVC, PVDF, SS304, SS316 etc.) to meet different solution needs<br />
* Available with the manual control and digital control model&nbsp;
</p>
</div>
</div>
</div>
<div>
<div>
<div id="43wbm">
<h3>
Control
</h3>
</div>
<div id="extp9">
<p>
* Manual stroke adjustment<br />
* Stroke actuator with 4-20mA signal<br />
* Digital controller with 4-20mA signal&nbsp;
</p>
</div>
</div>
</div>
</div>
<div>
<div id="32g4k">
<div id="ali-anchor-AliMaya-qxafv">
Our Team
</div>
</div>
<div>
<div>
<div id="9hf3h">
<div>
<img src="http://i.bosscdn.com/uploads/b4/8f/23/61e4d04422fe67e0071059bc15.jpg" width="325" height="216" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" /><img src="http://i.bosscdn.com/uploads/ec/ad/f3/5289e48655961d38cb13244dbe.jpg" width="325" height="216" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
</div>
</div>
<div>
<div id="xgr65">
<div id="ali-anchor-AliMaya-mpowd">
<div id="31eqw" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-m17fh" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Our Company
</div>
</div>
</div>
</div>
<div>
<div>
<div>
<div id="jxj2e">
<div>
<img src="http://i.bosscdn.com/uploads/bd/88/da/b2a030b5d4aabc778c1e948ce4.jpg" width="371" height="278" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" /><img src="http://i.bosscdn.com/uploads/f7/f5/a8/cbbc2cfe5314e68f6f6dc66786.jpg" width="371" height="278" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
</div>
</div>
<div>
<div id="17bfj">
<div>
<img src="http://i.bosscdn.com/uploads/9b/4a/67/1c8b5e6736e9819898a8109b57.jpg" width="750" height="515" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
</div>
<div>
<div id="pgksb">
<div id="ali-anchor-AliMaya-p86bu">
<div id="r3v7y" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-10s6p" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Our Certifications
</div>
</div>
</div>
</div>
<div>
<div id="cxfzs">
<div>
<img src="http://i.bosscdn.com/uploads/f9/21/56/8a1e04f95bcaefe55ac08e1317.jpg" width="148" height="211" title="Diaphragm Chemical Metering Pump" alt="Diaphragm Chemical Metering Pump" /><img src="http://i.bosscdn.com/uploads/bb/80/66/4361fdb18a55d2409b5eb16358.jpg" width="148" height="203" title="Diaphragm Chemical Metering Pump" alt="Diaphragm Chemical Metering Pump" /><img src="http://i.bosscdn.com/uploads/1c/6e/bd/b70b171b4025476974ff8d81b1.jpg" width="164" height="232" title="Diaphragm Chemical Metering Pump" alt="Diaphragm Chemical Metering Pump" /><img src="http://i.bosscdn.com/uploads/8e/fc/a7/f2cf9e9b0e0f9ef929eaa9bf1f.jpg" width="164" height="231" title="Diaphragm Chemical Metering Pump" alt="Diaphragm Chemical Metering Pump" />
</div>
</div>
</div>
</div>
<div>
<div id="sp1gv">
<div id="ali-anchor-AliMaya-lklxi">
<div id="elz0r" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-vts0f" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Customer Photo
</div>
</div>
</div>
</div>
<div>
<div id="pdtab">
<div>
<img src="http://i.bosscdn.com/uploads/62/28/ae/8a664457e96bbf8002d36d3fb0.jpg" width="480" height="320" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" /><img src="http://i.bosscdn.com/uploads/49/a2/8a/adf9bdef79c5eb9220b3dba766.jpg" width="480" height="320" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
</div>
<div>
<div id="jg035">
<div id="ali-anchor-AliMaya-9set5">
<div id="5m3tw" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-y9jay" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
FAQ
</div>
</div>
</div>
</div>
<div>
<div>
<div id="ehbd5">
<h3>
Q: Are you trading company or manufacturer ?
</h3>
</div>
<div id="haukz">
<p>
A: We are factory, and our factory has the independent research and development capacity
</p>
</div>
</div>
</div>
<div>
<div>
<div id="5vg0c">
<h3>
Q: How long is your delivery time?
</h3>
</div>
<div id="o73di">
<p>
A: Generally it is 3 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
</p>
</div>
</div>
</div>
<div>
<div>
<div id="mm0mz">
<h3>
Q: Do you provide samples ? is it free or extra ?
</h3>
</div>
<div id="s7cx6">
<p>
A: Yes, we could offer sample but it must be paid
</p>
</div>
</div>
</div>
<div>
<div>
<div id="q66y3">
<h3>
Q: What is your terms of payment ?
</h3>
</div>
<div id="u9i6u">
<p>
A:&nbsp;TT, LC. etc.....
</p>
</div>
</div>
</div>
</div>
</div>
<div>
</div>alipu.com

  其他類似產品
 
Food and Beverage Diaphragm Dosing Pump

Food and Beverage Diaphragm Dosing Pump
Hydraulical Diaphragm Dosing Pump

Hydraulical Diaphragm Dosing Pump
Mechanically driven diaphragms  Dosing pump

Mechanically driven diaphragms Dosing pump
H2SO4 & Soda Mechanical Diaphragm Dosing Pump

H2SO4 & Soda Mechanical Diaphragm Dosing Pump
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .