Cooling Water Treatment Chemical Solenoid Metering Pump 

  產品分類 : 機械與設備->整廠設備輸出->大底整廠設備及規劃

     
Cooling Water Treatment Chemical Solenoid Metering Pump
       

  產品規格
 
Model No:    JCMB55-25/2.0
  Country  CN
  Brand  AILIPU
  Packing  Strong carton packing suitable for the long distance transportation.
  Minimum Order  10
  Payment Term  L/C,T/T

 

  產品描述
   
  <div id="0m566" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-uj2j7" style="padding:8px 0px 4px 8px;color:#4D6599;font-size:22px;background-color:#C5CCDE;">
Product Description
</div>
</div>
<p style="font-size:13.3333px;">
<b>1. High Speed OperationL:&nbsp;</b><span style="font-size:13.3333px;">Up to 400 strokes per minute</span>
</p>
<p style="font-size:13.3333px;">
<b>2. Compact Size</b>
</p>
<p style="font-size:13.3333px;">
<b>3. Long Lasting Diaphragm:</b><span style="font-size:13.3333px;">&nbsp;The life of the diaphragm is over 5 years, which 5 times as national standard GB/T7782-2008</span>
</p>
<p style="font-size:13.3333px;">
<b>4. Strong Power Supply Compatibility:</b><span style="font-size:13.3333px;">&nbsp;smooth working stability in AC100-240V, and suitable for 50-60Hz range</span>
</p>
<p style="font-size:13.3333px;">
<b>5. High Protection Level</b>
</p>
<p style="font-size:13.3333px;">
<b>6. Double Valve Ball Structure</b>
</p>
<p style="font-size:13.3333px;">
<b><br />
</b>
</p>
<p>
<br />
</p>
<p>
<b>JCMB45 Model</b>
</p>
<p>
<br />
</p>
<div style="vertical-align:top;margin-left:-4px;">
<p>
<table class="MsoNormalTable" border="1" cellspacing="0" cellpadding="0" width="606" style="width:454.35pt;">
<tbody>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Model</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Flow</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Pressure</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Pipe Dia. (mm)</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Suction Pipe Material</span>
</p>
</td>
<td width="132">
<p class="MsoNormal">
<span style="font-size:8pt;font-family:'';">Discharge Pipe Material</span>
</p>
</td>
</tr>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB45–3/15</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">3.0 L/H</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">15bar</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In5.5 Out 9.5</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td width="132" valign="top">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB45–5/10</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">5.0 L/H</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">10bar</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In5.5 Out 9.5</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td width="132" valign="top">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB45–10/5</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">10 L/H</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">5bar</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In5.5 Out 9.5</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td width="132" valign="top">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span><b>&nbsp;</b>
</p>
</td>
</tr>
</tbody>
</table>
</p>
<p>
<br />
</p>
<p>
<b>JCMB55 Model</b>
</p>
<table class="MsoNormalTable" border="1" cellspacing="0" cellpadding="0" width="630" style="width:472.5pt;">
<tbody>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Model</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Flow</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Pressure</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Pipe Dia. (mm)</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Suction Pipe Material</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Discharge Pipe Material</span>
</p>
</td>
</tr>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB55–15/3.2</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">15 L/H</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">3.2bar</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In6.5 Out 9.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB55–20/2.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">20 L/H</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">2.5bar</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In6.5 Out 9.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB55–25/2.0</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">25 L/H</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">2.0bar</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In6.5 Out 9.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p>
<br />
</p>
<p>
<br />
</p>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="kpsek" style="vertical-align:top;">
<img src="http://i.bosscdn.com/uploads/12/54/cf/f1396c2fa3c03b2d0ad691c552.png" width="334" height="319" title="Solenoid pump outline dimention" alt="Solenoid pump outline dimention" /><img src="http://i.bosscdn.com/uploads/2e/08/3d/dfe342c4fc8412a9cde27828f4.png" width="371" height="340" title="Solenoid pump " alt="Solenoid pump " />
</div>
</div>
<p>
<br />
</p>
<div style="font-size:13.3333px;vertical-align:top;">
<div id="kmoa3" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-k4anm" style="padding:8px 0px 4px 8px;color:#4D6599;font-size:22px;background-color:#C5CCDE;">
JCMB Series
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="4tie7" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/b0/ab/13/329d8641bbdb9fd10530ef94e8.png" width="218" height="213" title="Solenoid metering pump manual control" alt="Solenoid metering pump manual control" />
</div>
<div style="vertical-align:top;">
<div id="0wlnb" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-S
</h3>
</div>
<div id="femn0" style="vertical-align:top;">
<p>
1. Manual &nbsp;flow&nbsp;adjusting&nbsp;
</p>
<p>
2. Pump On/Off indicator
</p>
<p>
3. Displayable frequency percentage
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="emv3o" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/ad/84/28/d5a06bcffafeacad193b2a0c1b.png" width="198" height="210" title="Solenoid metering pump Auto-Adjust (Digital impulse signal control)" alt="Solenoid metering pump Auto-Adjust (Digital impulse signal control)" />
</div>
<div style="vertical-align:top;">
<div id="qri9x" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-C Auto-Adjust (Digital impulse signal control)
</h3>
</div>
<div id="b8b7t" style="vertical-align:top;">
<p>
<span style="line-height:1.5;"></span>
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">&nbsp;(Digital pulse signal)&nbsp;</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="sb56z" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/f6/e4/43/4a67b2e29d7cc9ea21da0e8390.png" width="198" height="213" title="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" alt="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" />
</div>
<div style="vertical-align:top;">
<div id="4wpaw" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-H Auto-Adjust (4-20mA electric current signal control)
</h3>
</div>
<div id="dl8sl" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">&nbsp;(4-20mA electric current signal)&nbsp;</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="7qkbu" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/ca/84/f1/6c6de1b00ab4e61c2f98dcb72d.png" width="198" height="223" title="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback)" alt="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback)" />
</div>
<div style="vertical-align:top;">
<div id="iwxjz" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-F Auto-Adjust (Digital impulse signal control feedback)
</h3>
</div>
<div id="4kve8" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">(Digital pulse signal ) and feedback operating signal for remote control.</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="fnd6t" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/ca/84/f1/6c6de1b00ab4e61c2f98dcb72d.png" width="198" height="227" title="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback with Rs485 communication interface)" alt="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback with Rs485 communication interface)" />
</div>
<div style="vertical-align:top;">
<div id="r5xdx" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-CR Auto-Adjust (Digital impulse signal control feedback with Rs485 communication interface)
</h3>
</div>
<div id="vniw8" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">(Digital pulse signal ) and feedback operating signal for remote control&nbsp;</span><span style="line-height:1.5;">with Rs485 communication interface by MODBUS protocol.&nbsp;</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="wqhfh" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/f6/e4/43/4a67b2e29d7cc9ea21da0e8390.png" width="198" height="239" title="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" alt="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" />
</div>
<div style="vertical-align:top;">
<div id="3q6rp" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-H Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)
</h3>
</div>
<div id="wtypr" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received (4-20mA electric current signal) with Rs485 communication interface: using MODBUS protocol.&nbsp;
</p>
</div>
</div>
</div>
</div>
<div style="font-size:13.3333px;vertical-align:top;">
<div id="3xpeo" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-nrm29" style="padding:8px 0px 4px 8px;color:#4D6599;font-size:22px;background-color:#C5CCDE;">
Our Certifications
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="gjkj5" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/87/a4/cd/c38cdfb091fd015823217cce1d.jpg" width="146" height="207" title="ISO14001" alt="ISO14001" /><img src="http://i.bosscdn.com/product/51/8f/2b/c7315ca00623eaef75d1a2c084.jpg" width="148" height="208" title="ISO9001" alt="ISO9001" /><img src="http://i.bosscdn.com/product/36/c6/51/7f000be59064c20313593419fe.jpg" width="148" height="207" title="CE1" alt="CE1" /><img src="http://i.bosscdn.com/product/0a/90/af/83c57b8593eb3b7e52e84784ae.jpg" width="146" height="207" title="CE2" alt="CE2" />
</div>
</div>
</div>alipu.com

  其他類似產品
 
Stroke Automatic Diaphragm Pump

Stroke Automatic Diaphragm Pump
High Pressure Hydraulic Diaphragm Injection Pump

High Pressure Hydraulic Diaphragm Injection Pump
Water Treatment Electric Chemical Mechanical Diaphragm Dosing Pump

Water Treatment Electric Chemical Mechanical Diaphragm Dosing Pump
Chemical Hydraulic Diaphragm Metering Pump

Chemical Hydraulic Diaphragm Metering Pump
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .