登入 加入會員 求助
 
ShenzhenN-netTechnologyCo.,Ltd
 
 
Recommended Results 
 
EOC Ethernet to coax adapter 

  產品分類 : 服飾及紡織->配件->包包配件

     
EOC Ethernet to coax adapter
       

  產品規格
 
Model No:    NT-EN1400
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,T/T,Paypal,Western Union

 

  產品描述
   
  <p class="MsoNormal">
<br />
</p>
<div class="Section0">
<p class="MsoNormal" align="justify">
v&nbsp;Overview
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-EN1400 is a device for Ethernet transmission over coax featuring Coax to UTP connectivity, equipped with one Ethernet port and four BNC ports, which can make a ring or aggregation. So it can be used in pair or one to multi.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
The equipment can transmit signal over all kinds of common cables such as telephone line, Ethernet cable, UTP or coax etc., with excellent isolation, thunder prevention and anti-jamming function. In the practical project, this device is proved to be of high performance in surge prevention. It transmits IP video or Ethernet up to 1.5km at a max rate 70Mbps over existing coax, thus cut the cost by avoid re-cabling when swapping analog cameras for IP/Megapixel models.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-EN1400-AT (AF) series is POE version of model NT-EN1400, it can supply power over Ethernet cable for PD devices like HD cameras, wireless AP, IP telephone equipment. Our EOC support IEEE802.3af (15.4W) and IEEE802.3at (25.5W) standard.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-EN1400-AT (AF) series also supports POC (Power over Coax) function. Model at local side (namely the master) can supply power over coax cable for the model at remote side (the slave) and IP cameras.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
v&nbsp;Feature
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Modulation frequency: 2 MHz-28 MHz
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Modulation method: OFDM
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Encryption: AES128-bit encryption
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Networking: One Master and 7 Slaves
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Protocol:IEEE802.3/u 10Base-T, 100Base-TX, IEEE802.1Q VLAN, IEEE802.3af/at
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
* Support Auto-sensation of MDI/ MDIX at Ethernet port, compatible with NIC, switch and HUB etc.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Support up to 1522Bytes data packet
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Support Store and forward working mode; backpressure on Half-Duplex and flow control Full-Duplex.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Power supply range: DC 12V-56V
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Operation temperature: -20-70℃
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Support Ethernet ESD protection and EFT
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;POE (15.4W) and POE+ (25.5W) supported (optional)
</p>
<p class="MsoNormal">
<br />
</p>
</div>
<p>
<br />
</p>
<div class="Section1">
<p class="MsoNormal">
Specification
</p>
<p class="MsoNormal">
&nbsp;
</p>
<table class="MsoNormalTable">
<tbody>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal">
Parameter
</p>
</td>
<td width="524" valign="bottom" rowspan="2">
<p class="MsoNormal">
Specification
</p>
</td>
</tr>
<tr>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Design grade
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
Commercial Grade
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Rate
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
10/100Mbps
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Protocol
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
IEEE802.3/u, 10Base-T, 100Base-TX, IEEE802.1Q VLAN, IEEE802.3af/at
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal" align="center">
Transmission distance
</p>
</td>
<td width="524" valign="bottom">
<p class="MsoNormal">
Coax(SVY75-5): 1.5Km(TCP/IP up to 70Mbps)
</p>
</td>
</tr>
<tr>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
Cat 5: 100m
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal" align="center">
Port
</p>
</td>
<td width="524" valign="bottom">
<p class="MsoNormal">
one RJ45: connected to STP/UTP cat 5
</p>
</td>
</tr>
<tr>
<td width="524" valign="bottom" rowspan="2">
<p class="MsoNormal">
one BNC: Q9
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
&nbsp;
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Flow control
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
Duplex: flow control, Half Duplex: Backpressure
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal" align="center">
BER
</p>
</td>
<td width="524" valign="bottom" rowspan="2">
<p class="MsoNormal">
&lt;10-9
</p>
</td>
</tr>
<tr>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
MTBF
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
50,000 hours
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom">
<p class="MsoNormal">
&nbsp;
</p>
</td>
<td width="524" valign="bottom">
<p class="MsoNormal">
PWR- power,
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal" align="center">
LED indicator
</p>
</td>
<td width="524" valign="bottom">
<p class="MsoNormal">
LAN- link/ Act,
</p>
</td>
</tr>
<tr>
<td width="524" valign="bottom" rowspan="2">
<p class="MsoNormal">
Coax- coax cable connection
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom">
<p class="MsoNormal">
&nbsp;
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
&nbsp;
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
MASTER- master device monitoring
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Power supply
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
Input range:12~56 VDC
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Power
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
&lt;6W (when POE not working)
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Storage humidity
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
5%~90% Non condensation
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Working humidity
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
5%~90% Non condensation
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Working temperature
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
-20~70℃
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Storage temperature
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
-40~85℃
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Dimension
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
94mm×71mm×26mm
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Weight
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
&nbsp;
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom">
<p class="MsoNormal">
&nbsp;
</p>
</td>
<td width="524" valign="bottom">
<img src="http://i.bosscdn.com/product/e9/57/94/42ff8a96aec5fc54dfef82c228.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=29&p=5&t=80&text=bi1uZXQuYm9zc2dvby5jb20%3D" title="EOC" alt="EOC" /><br />
</td>
</tr>
</tbody>
</table>
</div>nnetswitch.com

  其他類似產品
 
L2 managed 10/100/1000M power over ethernet switch

L2 managed 10/100/1000M power over ethernet switch
unmanaged 10/100M POE switch

unmanaged 10/100M POE switch
industrial gigabit media converter

industrial gigabit media converter
L2 managed fast switch(poe optional

L2 managed fast switch(poe optional
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .