登入 加入會員 求助
 
ShenzhenN-netTechnologyCo.,Ltd
 
 
Recommended Results 
 
industrial unmanaged fast POE switch 

  產品分類 : 服飾及紡織->配件->包包配件

     
industrial unmanaged fast POE switch
       

  產品規格
 
Model No:    NT-IN128-4POE
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,T/T,Paypal,Western Union

 

  產品描述
   
  <p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
Overview
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-IN128 is Industrial Fast Ethernet Switch with 10 ports. It supports 8 port 10/100BASE-T and 2 port 100Base-X.
</p>
<p class="MsoNormal">
NT-IN128 series is packaged in a compact IP40 case that allows either DIN Rail or panel mounting for efficient usage of cabinet space.
</p>
<p class="MsoNormal">
NT-IN128-AT (AF) series can support 4 ports POE function, providing power supply for HD IP Camera, wireless AP, IP phone and so on. Our POE unmanaged Fast Ethernet Switch support&nbsp;up to&nbsp;IEEE802.3at, 25.5W&nbsp;PoE&nbsp;output.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Features
</p>
<p class="MsoNormal">
Built-in efficient switching core to implement flow control and reduce broadcast packets
</p>
<p class="MsoNormal">
Standard: IEEE802.3u 100BASE-FX, IEEE802.3u 100BASE-TX, IEEE802.3 10BASE-T, IEEE802.3x Flow Control, IEEE802.3at
</p>
<p class="MsoNormal">
10/100Base-TX can automatically identify the direct line and cross-line, is compatible with various cards,&nbsp;switches, HUB and other Ethernet devices.
</p>
<p class="MsoNormal">
It uses a store-and-forward mechanism to avoid packet loss and error frames
</p>
<p class="MsoNormal">
Support 8 standalone 10M/100Mbps&nbsp;Adaptive switched twisted-pair cable. Realize electricity back-up and mutil-user access
</p>
<p class="MsoNormal">
Support jumbo frame up to 1600Bytes
</p>
<p class="MsoNormal">
Support cut-through transmission&nbsp;and full-duplex flow control / half-duplex back pressure mode
</p>
<p class="MsoNormal">
12V to 48V DC or 24V AC Wide power input, redundant power and reverse polarity protection
</p>
<p class="MsoNormal">
-40 to 80℃&nbsp;operating temperature to meet a variety of complex environments
</p>
<p class="MsoNormal">
IP40 protection standard housing
</p>
<p class="MsoNormal">
Power port and Ethernet port supports ESD protection and EFT protection
</p>
<p class="MsoNormal">
DIN rail and panel mounting for efficient usage
</p>
<p class="MsoNormal">
Dual-fiber multi-mode, dual-fiber single-mode and single-fiber single-mode available,&nbsp;expanding&nbsp;the needs of users
</p>
<p class="MsoNormal">
Support POE power supply up to 25.5W (optional)
</p>
<p class="MsoNormal">
Provide up to 4K MAC address entries and built in 1.25 Mb RAM
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
Specifications:
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Parameter
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Specifications
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Design Level
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Industrial grade IP40 design standards
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Access mode
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
10/100Mbps
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Standard
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="18">
IEEE802.3u 100BASE-FX, IEEE802.3u 100BASE-TX, IEEE802.3 10BASE-T,
</p>
<p class="18">
IEEE802.3x Flow Control, IEEE802.3at
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Wavelength
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
1310nm/1550nm
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Transmission distance
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Dual-fiber multi-mode:2 km
</p>
<p class="MsoNormal">
Single fiber single mode: 20/&nbsp;40/&nbsp;60/&nbsp;80/&nbsp;100km
</p>
<p class="MsoNormal">
Dual-fiber single mode:&nbsp;20/&nbsp;40/&nbsp;60/&nbsp;80/&nbsp;100/&nbsp;120km
</p>
<p class="MsoNormal">
Category-5 twisted pairs: 100m
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Port
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Eight RJ45 port:&nbsp;
</p>
<p class="MsoNormal">
Connecting STP/UTP category-5 twisted pairs, EIA568A/B
</p>
<p class="MsoNormal">
Two optical port:&nbsp;
</p>
<p class="MsoNormal">
Multi-mode&nbsp;:SC/ FC/&nbsp;LC(50/125, 62.5/125μm)
</p>
<p class="MsoNormal">
Single mode : SC/ FC/&nbsp;LC (8.3/125, 8.7/125, 9/125 or 10/125μm)
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Conversion means
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Store and Forward mode
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Address table
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
4K
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Buffer space
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
1.25 Mbit
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Flow control
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Full duplex: flow control; Half duplex: back pressure
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Delay
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
store-and-forward:9.6us
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
BER
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
&lt;10-9
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
MTBF
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
50,000 hrs
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
LED indicator
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
POE1 ( POE1 power on/off), POE2 ( POE2 power on /off), POE3 ( POE3 power on/off),
</p>
<p class="MsoNormal">
POE4 ( POE4 power on/off), (1~8) UTP Port: L/A ,100
</p>
<p class="MsoNormal">
PWR1(PWR1 power on/off), PWR2(PWR2 power on/off)
</p>
<p class="MsoNormal">
F1(F1 Link/transmission), F2&nbsp;(F2 Link/transmission)
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Power supply
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Power Input Range: 12 ~ 48VDC/&nbsp;24VAC,
</p>
<p class="MsoNormal">
6-PIN Terminals, Redundant dual power
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Power consumption
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
7W
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Storage humidity
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
5%~90% non-condensing
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Operating humidity
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
5%~90% non-condensing
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Operating temperature
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
-40~80℃
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Storage Temperature
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
-40~85℃
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Dimensions
</p>
</td>
<td width="524" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
155mm×125mm×50mm&nbsp;(W×D×H)
</p>
</td>
</tr>
</tbody>
</table>
<br />
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="661" valign="center" colspan="2">
<p class="MsoNormal">
Certification
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMI
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC Part 15, CISPR (EN55022) class A
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMC
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC,CE
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMS
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-2 (ESD), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-3 (RS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-4 (EFT), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-5 (Surge), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-6 (CS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-8, Level 5
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-11
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Shock
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-27
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Free Fall
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-32
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Vibration
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-6
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Application
</p>
<p class="MsoNormal">
<img src="http://i.bosscdn.com/product/ab/98/d8/03d85d92021cb4e514387840bb.png@" title="NT-IN128" alt="NT-IN128" />
</p>
<p class="MsoNormal">
Dimensions
</p>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/33/b0/54/d006f3501a7cd978200af4f840.png@" title="NT-IN128(2)" alt="NT-IN128(2)" />
</p>nnetswitch.com

  其他類似產品
 
Industrial 1 fiber port switch

Industrial 1 fiber port switch
LCD 10/100M power over ethernet switch

LCD 10/100M power over ethernet switch
Fast industrial POE switch

Fast industrial POE switch
10/100/1000M internal fiber media converter

10/100/1000M internal fiber media converter
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .