登入 加入會員 求助
 
ShenzhenN-netTechnologyCo.,Ltd
 
 
Recommended Results 
 
low speed data industrial media converter 

  產品分類 : 服飾及紡織->配件->包包配件

     
low speed data industrial media converter
       

  產品規格
 
Model No:    NT-IN111D
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,T/T,Paypal,Western Union

 

  產品描述
   
  <p class="MsoNormal">
<p class="MsoNormal">
Overview
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
</p>
<p class="MsoNormal">
NT-IN111D&nbsp;is Industrial Fast Ethernet media converter&nbsp;equipped with&nbsp;one&nbsp;10/100M UTP port&nbsp;and&nbsp;low-speed data. It provides one 10/100Base-T ports, 3 low-speed data ports&nbsp;and one 100Bse-FX port. With strictly industrial design, it is fundamental guarantee for stability and practicability to flexible extends transmitting distance of the Ethernet and low speed data in the extreme industrial environment. &nbsp;&nbsp;
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;
</p>
<p class="MsoNormal">
Apply NT-IN111D industrial media converter equipping low-speed data port with NT-IN114D industrial&nbsp;switch, the buffering of heavy traffic burst, rate smoothing of network service and remote transmission of low-speed data can perfectly resolve, having the leading feature advantage in this field. &nbsp;
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-IN111D industrial media converter&nbsp;can install in control cabinet by adopting optional way of DIN-RIAL or Wall mount. It is a compact product, supporting wide working temperature, redundant power input, IP40 protection, LED indicator light, being a best choice for the industrial special application and a reliable solution for your industrial Ethernet connections.
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Features
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Procotols: IEEE802.3/u,&nbsp;10Base-T.100Base-TX
</p>
<p class="MsoNormal">
10/100Base-TX can automatically identify the direct line and cross-line, is compatible with Various cards, switches, HUB and other Ethernet devices
</p>
<p class="MsoNormal">
Take cut-through and forward technology, efficiently reducing the time-delay on network.
</p>
<p class="MsoNormal">
Support Max up to 11K Bytes packet transmission &nbsp;
</p>
<p class="MsoNormal">
Support cut-through transmission&nbsp;and full-duplex flow control / half-duplex back pressure mode
</p>
<p class="MsoNormal">
Support 3 low-speed data port, each can set as a separated RS232,RS485 or contact closure type.
</p>
<p class="MsoNormal">
Low-speed data passage adopt Time Division Multiplexing transmit, that makes low delay and easy apply without occupy IP address.
</p>
<p class="MsoNormal">
Low-speed data port support 0-115200bps speed
</p>
<p class="MsoNormal">
Low-speed data port support multi protection from lightning, surge, overvoltage and ESD
</p>
<p class="MsoNormal">
12V to 48V DC or 24V AC Wide power input, redundant power and reverse polarity protection
</p>
<p class="MsoNormal">
Support remote power off detection and indication
</p>
<p class="MsoNormal">
-40 To 80℃&nbsp;operating temperature to meet a variety of complex environments
</p>
<p class="MsoNormal">
IP40 protection standard housing
</p>
<p class="MsoNormal">
Power port and Ethernet port supports ESD protection and EFT protection
</p>
<p class="MsoNormal">
DIN rail and panel mounting for efficient usage
</p>
<p class="MsoNormal">
Support dual-fiber multi-mode, dual-fiber single-mode and single-fiber single-mode fiber port selection, expanded the needs of users
</p>
<p class="MsoNormal">
&nbsp;&nbsp;
</p>
<p class="MsoNormal">
Specification:
</p>
<p class="MsoNormal">
&nbsp;
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Parameter
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;&nbsp;Specifications
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Design Level
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Industrial grade IP40 design standards
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Access mode
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;10/100Mbps
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Standard
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
IEEE802.3/u.10Base-T.100Base-TX
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Wavelength
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;1310nm/1550nm
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Transmission distance
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Dual-fiber multi-mode:2 km
</p>
<p class="MsoNormal">
&nbsp;Single fiber single mode: 20/40/60/80/100 km
</p>
<p class="MsoNormal">
&nbsp;Dual-fiber single mode:20/40/60/80/100 /120 km
</p>
<p class="MsoNormal">
&nbsp;Category-5 twisted pairs: 100m
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Port
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;One&nbsp;RJ45 port:&nbsp;
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;Connecting STP/UTP category-5 twisted pairs, EIA568A/B
</p>
<p class="MsoNormal">
&nbsp;One optical port:&nbsp;
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;Multi-mode&nbsp;:SC / FC/LC(50/125, 62.5/125μm)
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;Single mode : SC / FC/LC (9/125)
</p>
<p class="MsoNormal">
&nbsp;3 low-speed data port,&nbsp;Industrial terminals, connecting to RS232,R485,contact closure according to the setting
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Conversion means
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Store and Forward mode or Time division
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Flow control
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Full duplex: flow control;
</p>
<p class="MsoNormal">
&nbsp;Half duplex: back pressure
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;BER
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;&lt;10-9
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;MTBF
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;50,000 hrs
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;LED indicator
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;L/A(Link/Transmit),100M(Speed),
</p>
<p class="MsoNormal">
PWR(Power),RPF(Remote power-off),SD(Fiber signal)
</p>
<p class="MsoNormal">
D1(Data passage 1 signal),D2(Data passage 2 signal),D3(Data passage 3 signal)
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Power supply
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power Input Range: 12 ~ 48VDC/24VAC ,
</p>
<p class="MsoNormal">
6-PIN Terminals, Redundant dual power, support power-off detection
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power consumption
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;&lt;2W (without PSE function)
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating temperature
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;-40~80ºC
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating humidity
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;5%~90% &nbsp;non-condensing
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Storage Temperature
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;-40~80ºC
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Storage humidity
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;5%~90% &nbsp;non-condensing
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Dimensions
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;155mm(length)×125mm(wide)×50mm(height)
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Weight
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Certification
</p>
<p class="MsoNormal">
&nbsp;
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="661" valign="center" colspan="2">
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;Certification
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMI
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC Part 15, CISPR (EN55022) class A
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMC
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC,CE
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMS
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-2 (ESD), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-3 (RS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-4 (EFT), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-5 (Surge), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-6 (CS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-8, Level 5
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-11
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Shock
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-27
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Free Fall
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-32
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Vibration
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-6
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Green product
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;RoHS
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Application&nbsp;
</p>
<p class="MsoNormal" align="center">
<img src="http://i.bosscdn.com/product/ac/a7/f8/4b3e469cbe3915c69e28ea4c79.png@" title="NT-IN111D" alt="NT-IN111D" />&nbsp;
</p>
<p class="MsoNormal">
Dimension
</p>
</p>
<p>
<img src="http://i.bosscdn.com/product/92/05/16/2f2235d86fb7337732aea9205c.png@" title="NT-IN111D(3)" alt="NT-IN111D(3)" />
</p>nnetswitch.com

  其他類似產品
 
Gigabit SFP Media Converter

Gigabit SFP Media Converter
L2 managed fast power over ethernet switch

L2 managed fast power over ethernet switch
10/100/1000M managed Ethernet switch

10/100/1000M managed Ethernet switch
L2 10/100M poe switch

L2 10/100M poe switch
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .