登入 加入會員 求助
 
ShenzhenN-netTechnologyCo.,Ltd
 
 
Recommended Results 
 
Fast Ethernet switch with 4 Ethernet ports 

  產品分類 : 服飾及紡織->配件->包包配件

     
Fast Ethernet switch with 4 Ethernet ports
       

  產品規格
 
Model No:    NT-G1400-AF4
  Country  CN
  Brand  N-net
  Packing  package
  Minimum Order  1
  Payment Term  L/C,T/T,Paypal,Western Union

 

  產品描述
   
  <p>
Overview
</p>
<ul>
<li>
The PoE feature enables the 4 Ethernet ports switch 10/100M&nbsp;an efficient and cost-effective solution for SMB, SOHO or other similar fields to deploy the PoE network for the wireless access points, IP-based surveillance cameras or IP phones anywhere easily and efficiently.
</li>
<li>
To satisfy the increasing demand of PoE for Gigabit Ethernet (GbE) networking, N-net has developed this series of PoE GbE switch.&nbsp;
</li>
<li>
The 4 Ethernet ports switch 10/100M&nbsp;is a 5-port GbE media converter, which provides 4X 10/100/1000BASE-T&nbsp;ports, which supports 802.3af PoE&nbsp;and 1X uplink 100/1000BASE-X port.
</li>
<li>
The 4 Ethernet ports switch 10/100M supports 60-Watt PoE budget to drive up to 4 IEEE 802.3af compliant powered devices simultaneously.&nbsp;
</li>
</ul>
Features
<ol>
<li>
Built-in efficient switching core to implement flow control and reduce broadcast packets
</li>
<li>
Standard Compliance:IEEE802.3 Ethernet, IEEE802.3u Gigabit Ethernet, IEEE802.3ab Gigabit Ethernet,
</li>
<li>
IEEE802.3z Gigabit Ethernet, IEEE802.3x Flow Control, IEEE802.3af PoE
</li>
<li>
Automatic identification of direct line and cross-line, compatible with various cards, switches, HUB and other Ethernet devices
</li>
<li>
Store-and-forward mechanism&nbsp;is employed&nbsp;to avoid packet loss and error frames
</li>
<li>
Support full-duplex flow control / half-duplex back pressure mode
</li>
<li>
Jumbo frames support a maximum of 9K bytes
</li>
<li>
48&nbsp;VDC power input
</li>
<li>
-20 To 70&nbsp;℃ operating temperature to meet a variety of complex environments
</li>
<li>
Copper&nbsp;ports&nbsp;support ESD protection
</li>
<li>
Support dual-fiber multi-mode, dual-fiber single-mode and single-fiber single-mode fiber port selection
</li>
<li>
Support PoE power supply up to maximum of 15W
</li>
</ol>
<p class="MsoNormal">
Specifications&nbsp;
</p>
<br />
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Parameter
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Specifications
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Access mode
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;10/100Mbps
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Standard
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;IEEE802.3 10Base-T Ethernet,
</p>
<p class="MsoNormal">
&nbsp;IEEE802.3u&nbsp;100Base-TX Fast Ethernet,
</p>
<p class="MsoNormal">
&nbsp;IEEE802.3x Flow control
</p>
<p class="MsoNormal">
&nbsp;IEEE802.3af POE
</p>
<p class="MsoNormal">
&nbsp;IEEE802.3at POE+
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Transmission distance
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Category-5 twisted pairs: 100m
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Port
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;RJ45 port:
</p>
<p class="MsoNormal">
&nbsp;Connecting with STP/UTP category-5 twisted pairs
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Flow control
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Full duplex: flow control; half duplex: back pressure
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Switch Architecture
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Store and Forward
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;MAC address table
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;1k auto-learning and aging
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Buffer Memory
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;512Kbit
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Switch Fabric
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;1.2Gbps
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Switch throughput
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;0.89Mpps @ 64bytes
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;MTU
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;1536bytes
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;LED indicator
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;PWR (power supply); L/A (fiber link/action); POE(PSE port is powering a PD)
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power supply
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;52VDC @ 1.25A 65W for 802.3af
</p>
<p class="MsoNormal">
&nbsp;52VDC @ 2.5A 130W for 802.3at
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power consumption
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;MAX. 3.5W
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;PoE power pins
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;RJ45 PIN1 &amp; 2: Pos(+) ; PIN3 &amp; 6: Neg(-)(for costumed 4/5: Pos(+), 7/8: Neg(-))
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating temperature
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;-20~70ºC
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating humidity
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;5%~90% &nbsp;non-condensing
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Maintaining temperature
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;-40~85ºC
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Maintaining humidity
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;5%~90% &nbsp;non-condensing
</p>
</td>
</tr>
<tr>
<td width="180" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Dimensions
</p>
</td>
<td width="485" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;190mm(W)×86mm(D)×30mm(H) (with ear-hangings)
</p>
<p class="MsoNormal">
&nbsp;176mm(W)x86mm(D)x30mm(H) (without ear-hangings)
</p>
</td>
</tr>
</tbody>
</table>
<p>
<br />
Product Picture
</p>
<p>
<img src="http://i.bosscdn.com/product/e1/dd/19/1686a375e4fe8f772bed50f590.jpg@" width="800" height="300" title="6 Port Power over Ethernet" alt="6 Port Power over Ethernet" />
</p>nnetswitch.com

  其他類似產品
 
fast Ethernet POE umanaged switch

fast Ethernet POE umanaged switch
unmanaged industrial Ethernet siwtch

unmanaged industrial Ethernet siwtch
power and ethernet over UTP cable converter

power and ethernet over UTP cable converter
10G fiber media converter

10G fiber media converter
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .